{"product_id":"kit-qlumen-one-step-rt-qpcr-sonda","title":"Kit qLUMEN One-Step per RT-qPCR con Sonda – per analisi RNA in tempo reale","description":"\u003cp data-start=\"921\" data-end=\"1164\"\u003eIl \u003cstrong data-start=\"924\" data-end=\"969\"\u003eKit qLUMEN One-Step per RT-qPCR con sonda\u003c\/strong\u003e è una soluzione pronta e ottimizzata per applicazioni di \u003cstrong data-start=\"1027\" data-end=\"1047\"\u003eRT-qPCR one-step\u003c\/strong\u003e, cioè per eseguire \u003cstrong data-start=\"1067\" data-end=\"1091\"\u003etrascrizione inversa\u003c\/strong\u003e e \u003cstrong data-start=\"1094\" data-end=\"1129\"\u003ePCR quantitativa in tempo reale\u003c\/strong\u003e all’interno della stessa provetta.\u003c\/p\u003e\n\u003cp data-start=\"1166\" data-end=\"1439\"\u003eÈ indicato per laboratori di \u003cstrong data-start=\"1195\" data-end=\"1218\"\u003ebiologia molecolare\u003c\/strong\u003e, genetica, microbiologia molecolare, virologia, diagnostica molecolare, ricerca universitaria, biotecnologie e controllo qualità che necessitano di analizzare target RNA con un workflow rapido, sensibile e riproducibile.\u003c\/p\u003e\n\u003cp data-start=\"1441\" data-end=\"1734\"\u003eIl kit comprende un \u003cstrong data-start=\"1461\" data-end=\"1477\"\u003eMasterMix 2X\u003c\/strong\u003e per realizzare PCR in tempo reale ed è compatibile con la maggior parte delle tecnologie di sonda. Include inoltre una miscela RT, formulata per supportare la sintesi di \u003cstrong data-start=\"1648\" data-end=\"1656\"\u003ecDNA\u003c\/strong\u003e e proteggere l’RNA durante la reazione. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1736\" data-end=\"1739\"\u003e\n\u003ch2 data-section-id=\"pjguh6\" data-start=\"1741\" data-end=\"1804\"\u003eRT-qPCR One-Step: retrotrascrizione e qPCR nello stesso tubo\u003c\/h2\u003e\n\u003cp data-start=\"1806\" data-end=\"1909\"\u003eLa tecnologia \u003cstrong data-start=\"1820\" data-end=\"1840\"\u003eone-step RT-qPCR\u003c\/strong\u003e permette di eseguire in un’unica reazione due passaggi fondamentali:\u003c\/p\u003e\n\u003cul data-start=\"1911\" data-end=\"2042\"\u003e\n\u003cli data-section-id=\"ltsxkp\" data-start=\"1911\" data-end=\"1971\"\u003econversione dell’RNA in cDNA tramite trascrizione inversa;\u003c\/li\u003e\n\u003cli data-section-id=\"1mkl172\" data-start=\"1972\" data-end=\"2042\"\u003eamplificazione e quantificazione del target mediante qPCR con sonda.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2044\" data-end=\"2242\"\u003eRispetto a un protocollo two-step, dove prima si sintetizza il cDNA e poi si prepara una seconda reazione qPCR, il sistema one-step riduce manipolazioni, tempi operativi e rischio di contaminazione.\u003c\/p\u003e\n\u003cp data-start=\"2244\" data-end=\"2391\"\u003eIn pratica: meno aperture di tubo, meno pipettaggi, meno possibilità che il banco laboratorio decida di trasformarsi in una crime scene molecolare.\u003c\/p\u003e\n\u003chr data-start=\"2393\" data-end=\"2396\"\u003e\n\u003ch2 data-section-id=\"akpfid\" data-start=\"2398\" data-end=\"2460\"\u003eIdeale per analisi RNA, virus e target molecolari specifici\u003c\/h2\u003e\n\u003cp data-start=\"2462\" data-end=\"2667\"\u003eIl Kit qLUMEN One-Step è pensato per analisi basate su \u003cstrong data-start=\"2517\" data-end=\"2524\"\u003eRNA\u003c\/strong\u003e come materiale di partenza. È particolarmente utile quando il laboratorio deve rilevare o quantificare target RNA mediante sonde fluorescenti.\u003c\/p\u003e\n\u003cp data-start=\"2669\" data-end=\"2708\"\u003ePuò essere utilizzato in workflow come:\u003c\/p\u003e\n\u003cul data-start=\"2710\" data-end=\"2986\"\u003e\n\u003cli data-section-id=\"1f8ljn8\" data-start=\"2710\" data-end=\"2742\"\u003eanalisi di espressione genica;\u003c\/li\u003e\n\u003cli data-section-id=\"knbxis\" data-start=\"2743\" data-end=\"2771\"\u003erilevazione di RNA virale;\u003c\/li\u003e\n\u003cli data-section-id=\"cf9l4e\" data-start=\"2772\" data-end=\"2808\"\u003estudi di microbiologia molecolare;\u003c\/li\u003e\n\u003cli data-section-id=\"prmkp6\" data-start=\"2809\" data-end=\"2843\"\u003eanalisi di target RNA specifici;\u003c\/li\u003e\n\u003cli data-section-id=\"19pdl5g\" data-start=\"2844\" data-end=\"2878\"\u003evalidazione di saggi molecolari;\u003c\/li\u003e\n\u003cli data-section-id=\"10eleo3\" data-start=\"2879\" data-end=\"2899\"\u003econtrollo qualità;\u003c\/li\u003e\n\u003cli data-section-id=\"uxjne4\" data-start=\"2900\" data-end=\"2933\"\u003ericerca in biologia molecolare;\u003c\/li\u003e\n\u003cli data-section-id=\"1vy68he\" data-start=\"2934\" data-end=\"2986\"\u003ediagnostica molecolare secondo protocollo interno.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2988\" data-end=\"3153\"\u003eLa combinazione tra RT e qPCR nello stesso tubo rende il prodotto adatto a workflow dove rapidità, sensibilità e riduzione delle manipolazioni sono aspetti centrali.\u003c\/p\u003e\n\u003chr data-start=\"3155\" data-end=\"3158\"\u003e\n\u003ch2 data-section-id=\"fc5yh5\" data-start=\"3160\" data-end=\"3198\"\u003eCompatibile con tecnologie di sonda\u003c\/h2\u003e\n\u003cp data-start=\"3200\" data-end=\"3358\"\u003eIl kit è progettato per qPCR con \u003cstrong data-start=\"3233\" data-end=\"3255\"\u003esonda fluorescente\u003c\/strong\u003e ed è compatibile con la maggior parte delle tecnologie di sonda. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3360\" data-end=\"3566\"\u003eLe sonde aumentano la specificità della rilevazione perché il segnale fluorescente dipende non solo dall’amplificazione del target, ma anche dal riconoscimento della sequenza specifica da parte della sonda.\u003c\/p\u003e\n\u003cp data-start=\"3568\" data-end=\"3820\"\u003eQuesto rende il sistema particolarmente indicato quando è necessario distinguere target specifici, ridurre la possibilità di interpretare prodotti aspecifici e ottenere risultati più affidabili rispetto ai sistemi basati solo su coloranti intercalanti.\u003c\/p\u003e\n\u003chr data-start=\"3822\" data-end=\"3825\"\u003e\n\u003ch2 data-section-id=\"n8a1bf\" data-start=\"3827\" data-end=\"3860\"\u003eMasterMix 2X per PCR real-time\u003c\/h2\u003e\n\u003cp data-start=\"3862\" data-end=\"3986\"\u003eIl kit include un \u003cstrong data-start=\"3880\" data-end=\"3921\"\u003eMasterMix fornito a concentrazione 2X\u003c\/strong\u003e per la PCR in tempo reale. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3988\" data-end=\"4211\"\u003eLa formulazione 2X semplifica la preparazione della reazione: l’operatore aggiunge RNA modello, primer, sonda e gli altri componenti previsti dal protocollo, mantenendo una base di reazione già ottimizzata e standardizzata.\u003c\/p\u003e\n\u003cp data-start=\"4213\" data-end=\"4332\"\u003eQuesto riduce il numero di passaggi manuali e migliora la riproducibilità tra campioni, operatori e sessioni di lavoro.\u003c\/p\u003e\n\u003chr data-start=\"4334\" data-end=\"4337\"\u003e\n\u003ch2 data-section-id=\"1gtzrt6\" data-start=\"4339\" data-end=\"4383\"\u003eMiscela RT con inibitori di RTasi e RNasi\u003c\/h2\u003e\n\u003cp data-start=\"4385\" data-end=\"4573\"\u003eLa scheda Labbox indica che il kit include una \u003cstrong data-start=\"4432\" data-end=\"4446\"\u003emiscela RT\u003c\/strong\u003e con una miscela equilibrata di componenti per la retrotrascrizione e inibitori di RNasi. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4575\" data-end=\"4806\"\u003eQuesto è un aspetto importante perché l’RNA è una molecola delicata e facilmente degradabile. La presenza di componenti dedicati alla fase RT e alla protezione dell’RNA aiuta a mantenere la qualità del campione durante la reazione.\u003c\/p\u003e\n\u003cp data-start=\"4808\" data-end=\"5028\"\u003eQuando si lavora con RNA, anche piccole contaminazioni da RNasi possono compromettere resa, sensibilità e riproducibilità. Quindi sì: qui la protezione dell’RNA non è un dettaglio, è praticamente la cintura di sicurezza.\u003c\/p\u003e\n\u003chr data-start=\"5030\" data-end=\"5033\"\u003e\n\u003ch2 data-section-id=\"1b9ptek\" data-start=\"5035\" data-end=\"5076\"\u003eDisponibile con ROX™ alto e ROX™ basso\u003c\/h2\u003e\n\u003cp data-start=\"5078\" data-end=\"5227\"\u003eIl Kit qLUMEN One-Step per RT-qPCR con sonda è disponibile in due versioni, entrambe per \u003cstrong data-start=\"5167\" data-end=\"5188\"\u003e100 test\/reazioni\u003c\/strong\u003e: \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5229\" data-end=\"5356\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5229\" data-end=\"5270\"\u003e\n\u003ctr data-start=\"5229\" data-end=\"5270\"\u003e\n\u003cth data-start=\"5229\" data-end=\"5241\" data-col-size=\"sm\" class=\"\"\u003eReferenza\u003c\/th\u003e\n\u003cth data-start=\"5241\" data-end=\"5255\" data-col-size=\"sm\" class=\"\"\u003eDescrizione\u003c\/th\u003e\n\u003cth data-start=\"5255\" data-end=\"5270\" data-col-size=\"sm\" class=\"\"\u003eNumero test\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5286\" data-end=\"5356\"\u003e\n\u003ctr data-start=\"5286\" data-end=\"5320\"\u003e\n\u003ctd data-start=\"5286\" data-end=\"5301\" data-col-size=\"sm\"\u003eRPCR-KPH-100\u003c\/td\u003e\n\u003ctd data-start=\"5301\" data-end=\"5313\" data-col-size=\"sm\"\u003eROX™ alto\u003c\/td\u003e\n\u003ctd data-start=\"5313\" data-end=\"5320\" data-col-size=\"sm\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5321\" data-end=\"5356\"\u003e\n\u003ctd data-start=\"5321\" data-end=\"5336\" data-col-size=\"sm\"\u003eRPCR-KPL-100\u003c\/td\u003e\n\u003ctd data-start=\"5336\" data-end=\"5349\" data-col-size=\"sm\"\u003eROX™ basso\u003c\/td\u003e\n\u003ctd data-start=\"5349\" data-end=\"5356\" data-col-size=\"sm\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"5358\" data-end=\"5603\"\u003eLa scelta tra \u003cstrong data-start=\"5372\" data-end=\"5385\"\u003eROX™ alto\u003c\/strong\u003e e \u003cstrong data-start=\"5388\" data-end=\"5402\"\u003eROX™ basso\u003c\/strong\u003e dipende dallo strumento real-time PCR utilizzato. Il ROX viene impiegato come riferimento passivo in diverse piattaforme qPCR per normalizzare variazioni di fluorescenza non legate all’amplificazione.\u003c\/p\u003e\n\u003chr data-start=\"5605\" data-end=\"5608\"\u003e\n\u003ch2 data-section-id=\"uznhzs\" data-start=\"5610\" data-end=\"5660\"\u003eDifferenza tra RT-qPCR One-Step e qPCR classica\u003c\/h2\u003e\n\u003cp data-start=\"5662\" data-end=\"5825\"\u003eLa \u003cstrong data-start=\"5665\" data-end=\"5682\"\u003eqPCR classica\u003c\/strong\u003e lavora generalmente su DNA o cDNA già preparato. Quindi, se il campione di partenza è RNA, serve prima una fase separata di retrotrascrizione.\u003c\/p\u003e\n\u003cp data-start=\"5827\" data-end=\"5969\"\u003eLa \u003cstrong data-start=\"5830\" data-end=\"5850\"\u003eRT-qPCR One-Step\u003c\/strong\u003e, invece, consente di partire direttamente dall’RNA e completare nello stesso tubo sia la sintesi del cDNA sia la qPCR.\u003c\/p\u003e\n\u003cp data-start=\"5971\" data-end=\"5982\"\u003eIn sintesi:\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5984\" data-end=\"6226\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5984\" data-end=\"6029\"\u003e\n\u003ctr data-start=\"5984\" data-end=\"6029\"\u003e\n\u003cth data-start=\"5984\" data-end=\"5994\" data-col-size=\"sm\" class=\"\"\u003eSistema\u003c\/th\u003e\n\u003cth data-start=\"5994\" data-end=\"6017\" data-col-size=\"sm\" class=\"\"\u003eCampione di partenza\u003c\/th\u003e\n\u003cth data-start=\"6017\" data-end=\"6029\" data-col-size=\"sm\" class=\"\"\u003eWorkflow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"6044\" data-end=\"6226\"\u003e\n\u003ctr data-start=\"6044\" data-end=\"6112\"\u003e\n\u003ctd data-start=\"6044\" data-end=\"6060\" data-col-size=\"sm\"\u003eqPCR classica\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6060\" data-end=\"6073\"\u003eDNA o cDNA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6073\" data-end=\"6112\"\u003eSolo amplificazione\/quantificazione\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6113\" data-end=\"6169\"\u003e\n\u003ctd data-start=\"6113\" data-end=\"6132\" data-col-size=\"sm\"\u003eRT-qPCR two-step\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6132\" data-end=\"6138\"\u003eRNA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6138\" data-end=\"6169\"\u003eRT separata + qPCR separata\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6170\" data-end=\"6226\"\u003e\n\u003ctd data-start=\"6170\" data-end=\"6189\" data-col-size=\"sm\"\u003eRT-qPCR one-step\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6189\" data-end=\"6195\"\u003eRNA\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6195\" data-end=\"6226\"\u003eRT + qPCR nello stesso tubo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"6228\" data-end=\"6365\"\u003eIl formato one-step è particolarmente utile quando si devono processare molti campioni, ridurre contaminazioni e velocizzare il workflow.\u003c\/p\u003e\n\u003chr data-start=\"6367\" data-end=\"6370\"\u003e\n\u003ch2 data-section-id=\"1quvhwj\" data-start=\"6372\" data-end=\"6398\"\u003eApplicazioni principali\u003c\/h2\u003e\n\u003cp data-start=\"6400\" data-end=\"6460\"\u003eIl Kit qLUMEN One-Step per RT-qPCR con sonda è indicato per:\u003c\/p\u003e\n\u003cul data-start=\"6462\" data-end=\"6835\"\u003e\n\u003cli data-section-id=\"1kd1ssz\" data-start=\"6462\" data-end=\"6481\"\u003eRT-qPCR one-step;\u003c\/li\u003e\n\u003cli data-section-id=\"1iq5sko\" data-start=\"6482\" data-end=\"6505\"\u003ereal-time PCR da RNA;\u003c\/li\u003e\n\u003cli data-section-id=\"u8o7mh\" data-start=\"6506\" data-end=\"6549\"\u003esintesi di cDNA e qPCR nello stesso tubo;\u003c\/li\u003e\n\u003cli data-section-id=\"1f8ljn8\" data-start=\"6550\" data-end=\"6582\"\u003eanalisi di espressione genica;\u003c\/li\u003e\n\u003cli data-section-id=\"knbxis\" data-start=\"6583\" data-end=\"6611\"\u003erilevazione di RNA virale;\u003c\/li\u003e\n\u003cli data-section-id=\"8e6mce\" data-start=\"6612\" data-end=\"6644\"\u003equantificazione di target RNA;\u003c\/li\u003e\n\u003cli data-section-id=\"6i41j0\" data-start=\"6645\" data-end=\"6672\"\u003emicrobiologia molecolare;\u003c\/li\u003e\n\u003cli data-section-id=\"16gzgf4\" data-start=\"6673\" data-end=\"6696\"\u003evirologia molecolare;\u003c\/li\u003e\n\u003cli data-section-id=\"nkto60\" data-start=\"6697\" data-end=\"6719\"\u003egenetica molecolare;\u003c\/li\u003e\n\u003cli data-section-id=\"1n66q54\" data-start=\"6720\" data-end=\"6744\"\u003ericerca universitaria;\u003c\/li\u003e\n\u003cli data-section-id=\"1ehdxrg\" data-start=\"6745\" data-end=\"6761\"\u003ebiotecnologie;\u003c\/li\u003e\n\u003cli data-section-id=\"10eleo3\" data-start=\"6762\" data-end=\"6782\"\u003econtrollo qualità;\u003c\/li\u003e\n\u003cli data-section-id=\"1vy68he\" data-start=\"6783\" data-end=\"6835\"\u003ediagnostica molecolare secondo protocollo interno.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6837\" data-end=\"6840\"\u003e\n\u003ch2 data-section-id=\"njxv3e\" data-start=\"6842\" data-end=\"6880\"\u003eCaratteristiche tecniche principali\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"6882\" data-end=\"7460\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"6882\" data-end=\"6912\"\u003e\n\u003ctr data-start=\"6882\" data-end=\"6912\"\u003e\n\u003cth data-start=\"6882\" data-end=\"6899\" data-col-size=\"sm\" class=\"\"\u003eCaratteristica\u003c\/th\u003e\n\u003cth data-start=\"6899\" data-end=\"6912\" data-col-size=\"md\" class=\"\"\u003eSpecifica\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"6923\" data-end=\"7460\"\u003e\n\u003ctr data-start=\"6923\" data-end=\"6979\"\u003e\n\u003ctd data-start=\"6923\" data-end=\"6934\" data-col-size=\"sm\"\u003eProdotto\u003c\/td\u003e\n\u003ctd data-start=\"6934\" data-end=\"6979\" data-col-size=\"md\"\u003eKit qLUMEN One-Step per RT-qPCR con sonda\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6980\" data-end=\"7020\"\u003e\n\u003ctd data-start=\"6980\" data-end=\"6992\" data-col-size=\"sm\"\u003eTipologia\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6992\" data-end=\"7020\"\u003eKit per RT-qPCR one-step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7021\" data-end=\"7052\"\u003e\n\u003ctd data-start=\"7021\" data-end=\"7034\" data-col-size=\"sm\"\u003eTecnologia\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7034\" data-end=\"7052\"\u003eqPCR con sonda\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7053\" data-end=\"7083\"\u003e\n\u003ctd data-start=\"7053\" data-end=\"7076\" data-col-size=\"sm\"\u003eCampione di partenza\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7076\" data-end=\"7083\"\u003eRNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7084\" data-end=\"7139\"\u003e\n\u003ctd data-start=\"7084\" data-end=\"7095\" data-col-size=\"sm\"\u003eWorkflow\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7095\" data-end=\"7139\"\u003eSintesi cDNA + qPCR in un’unica provetta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7140\" data-end=\"7176\"\u003e\n\u003ctd data-start=\"7140\" data-end=\"7152\" data-col-size=\"sm\"\u003eMasterMix\u003c\/td\u003e\n\u003ctd data-start=\"7152\" data-end=\"7176\" data-col-size=\"md\"\u003e2X per PCR real-time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7177\" data-end=\"7236\"\u003e\n\u003ctd data-start=\"7177\" data-end=\"7193\" data-col-size=\"sm\"\u003eCompatibilità\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7193\" data-end=\"7236\"\u003eMaggior parte delle tecnologie di sonda\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7237\" data-end=\"7261\"\u003e\n\u003ctd data-start=\"7237\" data-end=\"7250\" data-col-size=\"sm\"\u003eMiscela RT\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7250\" data-end=\"7261\"\u003eInclusa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7262\" data-end=\"7298\"\u003e\n\u003ctd data-start=\"7262\" data-end=\"7282\" data-col-size=\"sm\"\u003eVersione ROX alto\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7282\" data-end=\"7298\"\u003eRPCR-KPH-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7299\" data-end=\"7336\"\u003e\n\u003ctd data-start=\"7299\" data-end=\"7320\" data-col-size=\"sm\"\u003eVersione ROX basso\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7320\" data-end=\"7336\"\u003eRPCR-KPL-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7337\" data-end=\"7358\"\u003e\n\u003ctd data-start=\"7337\" data-end=\"7351\" data-col-size=\"sm\"\u003eNumero test\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"7351\" data-end=\"7358\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7359\" data-end=\"7429\"\u003e\n\u003ctd data-start=\"7359\" data-end=\"7371\" data-col-size=\"sm\"\u003eCategoria\u003c\/td\u003e\n\u003ctd data-start=\"7371\" data-end=\"7429\" data-col-size=\"md\"\u003eBiologia molecolare \/ Reagenti per biologia molecolare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"7430\" data-end=\"7460\"\u003e\n\u003ctd data-start=\"7430\" data-end=\"7442\" data-col-size=\"sm\"\u003eTrasporto\u003c\/td\u003e\n\u003ctd data-start=\"7442\" data-end=\"7460\" data-col-size=\"md\"\u003eCOLD_TRANSPORT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"7462\" data-end=\"7465\"\u003e\n\u003ch2 data-section-id=\"1fcukay\" data-start=\"7467\" data-end=\"7531\"\u003ePerché scegliere il Kit qLUMEN One-Step per RT-qPCR con sonda\u003c\/h2\u003e\n\u003cp data-start=\"7533\" data-end=\"7705\"\u003eIl \u003cstrong data-start=\"7536\" data-end=\"7581\"\u003eKit qLUMEN One-Step per RT-qPCR con sonda\u003c\/strong\u003e è una scelta ideale per laboratori che cercano una soluzione rapida e affidabile per analisi quantitative a partire da RNA.\u003c\/p\u003e\n\u003cp data-start=\"7707\" data-end=\"7734\"\u003eI principali vantaggi sono:\u003c\/p\u003e\n\u003cul data-start=\"7736\" data-end=\"8136\"\u003e\n\u003cli data-section-id=\"1rhlbf2\" data-start=\"7736\" data-end=\"7775\"\u003econsente RT e qPCR nello stesso tubo;\u003c\/li\u003e\n\u003cli data-section-id=\"1exorwd\" data-start=\"7776\" data-end=\"7807\"\u003eriduce tempi e manipolazioni;\u003c\/li\u003e\n\u003cli data-section-id=\"1120xnf\" data-start=\"7808\" data-end=\"7850\"\u003ediminuisce il rischio di contaminazione;\u003c\/li\u003e\n\u003cli data-section-id=\"1rxlnua\" data-start=\"7851\" data-end=\"7908\"\u003eutilizza tecnologia con sonda per maggiore specificità;\u003c\/li\u003e\n\u003cli data-section-id=\"1k4az98\" data-start=\"7909\" data-end=\"7970\"\u003ecompatibile con la maggior parte delle tecnologie di sonda;\u003c\/li\u003e\n\u003cli data-section-id=\"1dabr7l\" data-start=\"7971\" data-end=\"8012\"\u003einclude MasterMix 2X per PCR real-time;\u003c\/li\u003e\n\u003cli data-section-id=\"hcv6c5\" data-start=\"8013\" data-end=\"8034\"\u003einclude miscela RT;\u003c\/li\u003e\n\u003cli data-section-id=\"bjnzc0\" data-start=\"8035\" data-end=\"8084\"\u003edisponibile con \u003cstrong data-start=\"8053\" data-end=\"8066\"\u003eROX™ alto\u003c\/strong\u003e o \u003cstrong data-start=\"8069\" data-end=\"8083\"\u003eROX™ basso\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"v9sqot\" data-start=\"8085\" data-end=\"8111\"\u003eformato da \u003cstrong data-start=\"8098\" data-end=\"8110\"\u003e100 test\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli data-section-id=\"1ggbj8k\" data-start=\"8112\" data-end=\"8136\"\u003etrasporto refrigerato.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"8138\" data-end=\"8320\"\u003eRispetto a un sistema qPCR standard, questo kit è più indicato quando il materiale di partenza è RNA e si desidera combinare retrotrascrizione e quantificazione in un unico workflow.\u003c\/p\u003e\n\u003col\u003e\u003c\/ol\u003e","brand":"Gquence","offers":[{"title":"ROX alto","offer_id":47595066130772,"sku":"RPCR-KPH-100","price":252.0,"currency_code":"EUR","in_stock":true},{"title":"ROX basso","offer_id":47595066163540,"sku":"RPCR-KPL-100","price":248.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0792\/8938\/5300\/files\/RPCR-KGH-001-scaled.jpg?v=1707671406","url":"https:\/\/www.diellelab.com\/products\/kit-qlumen-one-step-rt-qpcr-sonda","provider":"DIELLELAB","version":"1.0","type":"link"}